JR Reverse Osmosis System (JR – BWRO)

JR SYSTEMS Brackish Water Reverse Osmosis is used to treat water from any source including surface water and wells, which may be turbid, saline or have arsenic, nitrates or any other contaminants.

 

SMALL SCALE BRACKISH WATER RO PLANT –

TECHNICAL SPECIFICATION

PART NUMBER

RO 1000 LPH

RO 2000 LPH

RO 3000 LPH

RO 4000 LPH

RO 5000 LPH

CAPACITY

20 Cubic meter/Day (20 TPD)

40 Cubic meter/Day (40 TPD)

60 Cubic meter/Day (60 TPD)

80 Cubic meter/Day 80 TPD)

100 Cubic meter/Day (100 TPD)

MEMBRANE SIZE X UNIT

8040 x 1

8040 x 2

8040 x 3

8040 x 4

8040 x 5

MEMBRANE MAKE

GE/HYDRANAUTICS

GE/HYDRANAUTICS

GE/HYDRANAUTICS

GE/HYDRANAUTICS

GE/HYDRANAUTICS

MEMBRANE HOUSING

300 psi / 8 inch 1 element Long

300 psi / 8 inch 2 element Long

300 psi / 8 inch 3 element Long

300 psi / 8 inch 2x2element Long

300 psi / 8 inch 5 element Long

WATER QUALITY MONITOR

TDS METER WITH LCD DISPLAY / HANNA –USA

HIGH PRESSURE PUMP

2 HP/ VERTICAL MULTISTAGE PUMP

4 HP/ VERTICAL MULTISTAGE PUMP

6 HP/ VERTICAL MULTISTAGE PUMP

8 HP/ VERTICAL MULTISTAGE PUMP

10 HP/ VERTICAL MULTISTAGE PUMP

PUMPS

GRUNDFOS/LOWARA/CRI/CROMPTON/JOHNSON/KRILOSKAR

FRMAES PARTS

MSEP/SS

MSEP/SS

MSEP/SS

MSEP/SS

MSEP/SS

FLOW METER

Rota meter / Flow max

DIMENSION (m)

2×1.5×1.5

2×1.5×1.5

2x2x1.5

2.5×2.5×1.5

3x3x2

Weight (kg)

950

1050

1200

1500

1600

PRE FILTRATION

DMF

DMF

DMF

DMF

DMF

OPERATION

AUTO/MANUAL

AUTO/MANUAL

AUTO/MANUAL

AUTO/MANUAL

AUTO/MANUAL

DOSING SYSTEM

P

P

P

P

P

RAW WATER PUMP

P

P

P

P

P

ELECTRICAL CONTROL

AUTO/MANUAL MODE (MICROPROCESSOR BASED OPERATION / PLC)